The Netbell-2-2Buz is a one-stop break buzzer system for factories, warehouses, and industrial facilities that need to signal shift changes, breaks, and other timed alerts in areas with high ambient noise. The kit includes a Netbell-2 web-based bell controller and two 4-inch extra loud buzzers (110 dBA @ 1m) with weatherproof back boxes — everything needed for installation and operation. The controller is built on a TCP/IP platform with a built-in web server, so you can access, control, and schedule your buzzers over the network or the Internet from any browser, with no additional software and no dedicated computer required. With the digital inputs you can also wire a push switch to sound the buzzers manually in an emergency. It’s an affordable way for any facility to replace an old bell timer with a modern warehouse buzzer system.

How It Works

  • Wire the buzzer to the power supply.
  • Connect the buzzer to the Netbell-2 bell controller.
  • Power the controller and connect it to your network — it can go anywhere on your network, no direct PC connection needed.
  • Add buzzer schedules from a standard web browser (or the free BellScheduler desktop app) — up to 500 events.

The Key Features

  • COMPLETE BUZZER KIT — Affordable break buzzer system with a Netbell-2 web-based controller and one 110 dB bell kit; everything to replace an old bell system.
  • SCHEDULE FROM ANY BROWSER — Program up to 500 bell events from any browser or the free BellScheduler app; no monthly fees.
  • NETWORK OR STANDALONE — Works anywhere on your network, or load a schedule and run it offline as a standalone device.
  • COVERS UP TO 25,000 SQ FT — Included 4-inch extra loud buzzer covers up to 25,000 sq ft; wire a push switch for manual emergency ringing.
  • MADE IN THE USA — A simple, low-cost way to modernize a warehouse or factory bell system; built in the USA.

What’s in the Box

  • One Netbell-2 bell controller
  • Two extra loud buzzer kits

Specifications for the Controller

Power Input: 12-48 VDC

Bell Outputs: 2 bell outputs, dry contact, Normal Open (NO), 8A @ 30VDC

Digital Inputs: 2

Schedules: Up to 500 events

Bells Scheduler: Weekday or calendar-based: (HH:MM:SS, MM/DD/YYYY, SUNDAY-SATURDAY)

User settable duration: mS, Sec, Min

Real-Time Clock:

  • NTP automatic Internet time setting
  • NTP Sync period: User settable
  • Automatic Daylight Savings adjustment

Battery (capacitor) Power Backup:

  • Capacitor power Backup
  • Backup Functions: Retain Real-Time Clock, basic settings
  • Backup Duration: 2 weeks minimum

Network

  • Type: 10/100 Base-TX POE Ethernet Port
  • POE (for controller only): IEEE 802.3af
  • Setup: Static or DHCP IP address configuration

Physical

  • Operating Temperature: 0 to +70 Celsius
  • Storage temperature: -40 to +125 Celsius
  • Humidity: 10% to 90% non-condensing
  • Dimensions: 125mm x 175mm x 80mm
  • Weight: 1lbs
  • Protocols: DHCP, DNS, TCP/IP (IPv4), UDP, HTTP

Buzzer Kit

  • 4" Inch 24VAC 50/60Hz
  • Zinc Die-cast housing Enclosure and Sealed with Grey Powder-coat Paint
  • Decibels: 100dBa @ 10', 110dBa @ 1m
Download the Documentation

Netbell Quick Setting Instruction
Netbell-User-Manual.pdf
Use-Push-Switch-To-Ring-Bell-Manually-for-Emergency.pdf

Software Configuration

Download the Discover app to find the IP address on your network

Download the Discover App for Windows from the link below (the file is a ZIP file – please extract after downloading):

Linortek Discover for Windows

Alternatively, you can download the Java-based Discover program if you believe you have the Java runtime installed on your PC, you can download the Java-based Discover program here (the file is a ZIP file – please extract after downloading):
Linortek-TCPIP-Discoverer.zip

Download the Netbell BellScheduler Desktop App and Instructions

If you own one Netbell device, it will be easy to add bell schedules from the webpage of your device. However, if you have multiple Netbell devices, you can use our free BellScheduler desktop app to add bell schedules from a single interface.

Netbell-BellScheduler-Desktop-App-Setting-Instruction.pdf Netbell-BellScheduler.zip

Video Tutorials

How to wire a buzzer to Netbell-2
How to wire a bell to the Netbell-2
Use a Push Button Switch on Netbell-2 for Emergency
Finding the IP address using the Discover program
Netbell Software Initial Setup – Basic Settings
How to Use the Netbell BellScheduler Desktop App
Reset to Factory Default

FAQs

General Questions
Network Questions
Netbell Configuration Questions

People Also Love

Related Products

An IP-based overhead paging system for schools, and other facilities that can be used for emergency alerts, break time scheduling,...
Price range: $334.00 through $1,319.00
An IP-based overhead paging system for warehouses, factories, schools, and industrial facilities that can be used for emergency alerts, break...
Price range: $334.00 through $1,319.00
A network-enabled, cost-effective industrial paging system designed for manufacturing facilities, distribution centers, and industrial warehouses requiring consistent break timing and...
Price range: $334.00 through $1,319.00
The Netbell-4-4Buz includes everything needed for factories, industrial facilities, warehouses to build a fully automated web-based timed alert system for...
$2,332.00
Replace your outdated bell timer system with the Netbell web-based solution. This cost-effective Netbell-4-4Bel includes everything — controller, bells, and...
$1,892.00