Break Buzzer System for Warehouse Factory Break Time Alarm Bell Web-Based Controller Covers Up to 25K Sq.ft - Netbell-2-1Buz

$873.00

Replace your outdated bell timer system with the Netbell web-based solution. This cost-effective Netbell-2-1Buz includes everything — controller, buzzers, and and web-based software — ready to connect and run. Manage up to 500 bell schedules from any web browser, no dedicated software, no keypad programming. Each extra loud buzzer (110 dB ) covers up to 25,000 sq. ft.

Need more bells or different options such as a digital clock? Build your complete system

The Netbell-2-1Buz is a one-stop solution that comes with everything needed for installation and operation a buzzer system. The kit includes one Netbell-2 networked bell controller, two extra loud buzzer kit (volume adjustable). Each buzzer kit comes with one 4-inch buzzer, one weatherproof back box for wall mounting and one 24VAC power supply to power the buzzer, one 10ft power cable. The Netbell-2 web-based bell controller is built on a TCP/IP platform with a built-in web server and special software designed for scheduling a bell system. With the built-in web interface, you can access, control and schedule bells over a network or the Internet, no additional software or designated computer required. With the digital inputs you can wire a push switch for ringing bells manually for emergency.  It’s an ideal solution for warehouses, factories to build a fully automated web-based timed alert system for signaling start and stop works, shift rotations, breaks and any other timed signal applications.

It’s ready to go out of the box, wire the buzzer to one of the bell (relay) outputs of the Netbell-2 controller, plug the controller to the power outlet with the provided power supply, and connect it to the network switch with the provided cables, it can be connected anywhere on the network and does not require a direct connection to a PC. Scheduling and setup are accessed through any standard web browser or BellScheduler desk app. For those who wish to forego networking the Netbell, it is also able to function as a stand-alone device. Connecting the unit to a PC, add the bell schedules, then remove, and it will function as scheduled.

How It Works

  • Wire the buzzer to the power supply.
  • Connect the buzzer to the Netbell-2 bell controller.
  • Power the controller and connect it to your network — it can go anywhere on your network, no direct PC connection needed.
  • Add bell schedules from a standard web browser (or the free BellScheduler desktop app) — up to 500 events.

What is in the box

  • One Netbell-2 bell controller
  • One buzzer kit

The Key Features

  • COMPLETE BUZZER KIT — Affordable break buzzer system with a Netbell-2 web-based controller and one 110 dB bell kit; everything to replace an old bell system.
  • SCHEDULE FROM ANY BROWSER — Program up to 500 bell events from any browser or the free BellScheduler app; no monthly fees.
  • NETWORK OR STANDALONE — Works anywhere on your network, or load a schedule and run it offline as a standalone device.
  • COVERS UP TO 25,000 SQ FT — Included 4-inch extra loud buzzer covers up to 25,000 sq ft; wire a push switch for manual emergency ringing.
  • MADE IN THE USA — A simple, low-cost way to modernize a warehouse or factory bell system; built in the USA.

Specifications for the Controller

Power Input: 12-48 VDC

Bell Outputs: 2 bell outputs, dry contact, Normal Open (NO), 8A @ 30VDC

Digital Inputs: 2

Schedules: Up to 500 events

Bells Scheduler: Weekday or calendar-based: (HH:MM:SS, MM/DD/YYYY, SUNDAY-SATURDAY)

User settable duration: mS, Sec, Min

Real-Time Clock:

  • NTP automatic Internet time setting
  • NTP Sync period: User settable
  • Automatic Daylight Savings adjustment

Battery (capacitor) Power Backup:

  • Capacitor power Backup
  • Backup Functions: Retain Real-Time Clock, basic settings
  • Backup Duration: 2 weeks minimum

Network

  • Type: 10/100 Base-TX POE Ethernet Port
  • POE (for controller only): IEEE 802.3af
  • Setup: Static or DHCP IP address configuration

Physical

  • Operating Temperature: 0 to +70 Celsius
  • Storage temperature: -40 to +125 Celsius
  • Humidity: 10% to 90% non-condensing
  • Dimensions: 125mm x 175mm x 80mm
  • Weight: 1lbs
  • Protocols: DHCP, DNS, TCP/IP (IPv4), UDP, HTTP

Buzzer Kit

  • 4" Inch 24VAC 50/60Hz
  • Zinc Die-cast housing Enclosure and Sealed with Grey Powder-coat Paint
  • Decibels: 100dBa @ 10', 110dBa @ 1m
Download the Documentation

Netbell Quick Setting Instruction
Netbell-User-Manual.pdf
Use-Push-Switch-To-Ring-Bell-Manually-for-Emergency.pdf

Software Configuration

Download the Discover app to find the IP address on your network

Download the Discover App for Windows from the link below (the file is a ZIP file – please extract after downloading):

Linortek Discover for Windows

Alternatively, you can download the Java-based Discover program if you believe you have the Java runtime installed on your PC, you can download the Java-based Discover program here (the file is a ZIP file – please extract after downloading):
Linortek-TCPIP-Discoverer.zip

Download the Netbell BellScheduler Desktop App and Instructions

If you own one Netbell device, it will be easy to add bell schedules from the webpage of your device. However, if you have multiple Netbell devices, you can use our free BellScheduler desktop app to add bell schedules from a single interface.

Netbell-BellScheduler-Desktop-App-Setting-Instruction.pdf Netbell-BellScheduler.zip

Video Tutorials

How to wire a buzzer to Netbell-2
How to wire a bell to the Netbell-2
Use a Push Button Switch on Netbell-2 for Emergency
Finding the IP address using the Discover program
Netbell Software Initial Setup – Basic Settings
How to Use the Netbell BellScheduler Desktop App
Reset to Factory Default

FAQs

General Questions
Network Questions
Netbell Configuration Questions

People Also Love

Related Products

An IP-based overhead paging system for schools, and other facilities that can be used for emergency alerts, break time scheduling,...
Price range: $334.00 through $1,319.00
An IP-based overhead paging system for warehouses, factories, schools, and industrial facilities that can be used for emergency alerts, break...
Price range: $334.00 through $1,319.00
A network-enabled, cost-effective industrial paging system designed for manufacturing facilities, distribution centers, and industrial warehouses requiring consistent break timing and...
Price range: $334.00 through $1,319.00
The Netbell-4-4Buz includes everything needed for factories, industrial facilities, warehouses to build a fully automated web-based timed alert system for...
$2,332.00
Replace your outdated bell timer system with the Netbell web-based solution. This cost-effective Netbell-4-4Bel includes everything — controller, bells, and...
$1,892.00